на главную страницу Equipment
Mapgo to main pageSend e-mail Equipment • Sensor coupling modules

 

MSAP
Sensor coupling modules

Designed for analog-to-digital conversion of the signal coming from the sensor, preprocessing and transmitting the result to a recording apparatus hereinafter.n general, the ICAP sends the result in digital form via the RS-485 interface. ICAP also can serve as a sensor signal amplifier or signal converter (if necessary change electrical signal parameter).

Type of connected sensor Input signal range
bridge tensoresistance 0 ... 20 mV
potentiometer 0 ... 1405 Ohm
potentiometer 0 ... 176 Ohm
potential0...10 V
current 0 ... 20 mA

Principal parameters

interface RS-485
nominal power supply (DC)12 V
current consumption not more then 40 mA
nominal range of the output voltage 0...5 V
bit converter (ADC and DAC) 12 bit
Operating temperature rangefrom -40°C to +80°C
running timeunlimited
Dimensions (height x width x depth)105 x 82 x 68 mm
massnot more then 0.4 kg
probability of failure-free operation for 50 hours at least 0.96
average time to retirement not less 5 years
category accuracy 1
explosion-proofing marks 0ExiaIICT6
Ingress protection as by GOST 14254-96IP66

 

monitoring I simulators I equipment I training