MSAP Sensor coupling modules
Designed for analog-to-digital conversion of the signal coming from the sensor, preprocessing and transmitting the result to a recording apparatus hereinafter.n general, the ICAP sends the result in digital form via the RS-485 interface. ICAP also can serve as a sensor signal amplifier or signal converter (if necessary change electrical signal parameter).
Type of connected sensor | Input signal range |
bridge tensoresistance | 0 ... 20 mV |
potentiometer | 0 ... 1405 Ohm |
potentiometer | 0 ... 176 Ohm |
potential | 0...10 V |
current | 0 ... 20 mA |
|
|
Principal parameters
interface | RS-485 |
nominal power supply (DC) | 12 V |
current consumption | not more then 40 mA |
nominal range of the output voltage | 0...5 V |
bit converter (ADC and DAC) | 12 bit |
Operating temperature range | from -40°C to +80°C
| running time | unlimited |
Dimensions (height x width x depth) | 105 x 82 x 68 mm |
mass | not more then 0.4 kg |
probability of failure-free operation for 50 hours | at least 0.96 |
average time to retirement | not less 5 years |
category accuracy | 1 |
explosion-proofing marks | 0ExiaIICT6 |
Ingress protection as by GOST 14254-96 | IP66 |
|
monitoring I simulators I equipment I training |
|
|
 |